Neon and LED troubleshooting

Most sign faults have a handful of causes. This guide lists the common symptoms we hear about on the phone, what usually causes them and what to check first. Always isolate the supply before touching a sign, and remember that neon power supplies produce high voltage.

Glass neon

Tube won't light at all

  • Protection has tripped. Electronic convertors over 990V and SIET transformers have earth leakage and open circuit protection. A broken tube, a loose HT connection or moisture can trip it. Find and fix the fault, then switch off and on to reset.
  • Broken or cracked tube, or a leak. A tube that has lost its vacuum won't light, or shows a weak, pale glow.
  • No mains. Check the supply, the switch and any timer or firefighter's switch.

Tube flickers or "dances"

  • The power supply doesn't have enough voltage for the length of glass. Recheck the glass length with the neon voltage calculator.
  • Impurities in the tube from processing. The tube may need re-pumping.
  • A poor connection on an electrode or HT cable.

Electrode end runs hot or glows

  • The current is too high for the electrode or tube. Check the electrode type against the current in our electrode guide.
  • Impurities in the tube.

Blackening near the electrodes

This is usually caused by running the electrode above its recommended current, or by age. It shortens tube life.

Blue or coloured tubes look patchy or dim in cold weather

Argon/mercury tubes can look uneven when cold, until the mercury vapour spreads through the tube. Give them time to warm up. If it doesn't clear, the tube may be low on mercury.

Earth leakage keeps tripping

  • Moisture in an outdoor sign, or condensation in a box.
  • HT cable damaged, too long, or run in metal conduit or close to earthed metalwork.
  • Electrode connections without silicone covers, or covers that have perished.

Buzzing

Traditional transformers can hum. A loud buzz from a convertor, or a crackle from the sign, can mean a loose fixing or an HT discharge. Switch off and check the cable routes and connections.

LED

Modules are dimmer at the end of the run

  • Too many modules on one run. Feed from more than one point. The maximum per run is on each product page.
  • Voltage drop on a long or thin cable. Check with the voltage drop calculator.

LEDs flicker or switch on and off

  • The power supply is overloaded, or protecting itself against a short. Recheck the load with the power supply calculator and look for damaged cable.
  • A loose connection or a failed connector.

Nothing lights

  • Polarity reversed (red to +, black to -).
  • Wrong supply voltage. Check the supply matches the modules (12V or 24V). Over-voltage can destroy modules.
  • Failed supply. Measure the output with a meter.

One colour missing on RGB

Check the colour wiring at each joint and at the controller. One channel may be wired to the wrong terminal or have a broken joint.

Power supply fails early

Heat is the usual cause: a supply sealed in a small box, run near full load or in direct sun. Leave headroom (no more than 80% load) and airflow. Outdoors, use an IP67 supply.

Still stuck?

Call us on 01892 783 900, Monday to Friday, 9am to 5pm, with the product codes and what the sign is doing.