Hansen EVG convertor or SIET Metalbox transformer for glass neon?

Electronic convertor or wound transformer? We sell both, Hansen EVG convertors and SIET Metalbox transformers, and the right one depends on the tube load, where the sign is going and how it's controlled. Here's what we check.

Hansen EVG convertors

  • Small and light. Many sign makers fit them inside letters and boxes, but check the model's dimensions and the mounting notes in Hansen's installation advice first.
  • Constant current electronic units. Models above 990V have earth leakage and open circuit protection built in.
  • The 990V models (EVG 20/1, 40/1 and 60/1) only drive short lengths. As a guide, about 1.4m of 15mm blue tube on one output outdoors.
  • The 5kV and 8kV models aren't for outdoor use. Don't extend the HT cables on any Hansen unit.
  • Only the D (dimmable) versions can be dimmed, on a trailing edge (reverse phase) dimmer. The exceptions are the 20/5D and 20/8D, which only dim with the screw-on dimming unit.

SIET Metalbox transformers

  • Wound transformers in a metal case, rated IP44, with an earth leakage trip inside. IP44 isn't a blanket pass for every outdoor position, so follow SIET's mounting instructions.
  • Available in a range of voltage and current ratings for bigger circuits.
  • They dim on leading edge dimmers. To dim one, the internal Distop has to be removed and an external earth leakage device fitted. Talk to us before you dim or flash one.

How to size either type

  1. Measure the glass on each circuit and note the tube diameter. Keep each circuit separate.
  2. Note the gas. Neon (red) needs a higher voltage than blue (argon/mercury).
  3. Put the diameter, number of sections and total length into the neon calculator. It gives a voltage for each gas and for Hansen and SIET. It's an estimate and doesn't include electrode length.
  4. Pick the electrode for the tube diameter and keep within its current: 8mm and 10mm tube on 25R (EL025) electrodes at 20mA, 25mA maximum; 12mm on 50R (EL050), 50mA maximum; 15mm on 80R (EL080), 80mA maximum; bigger tube on 150R or 250R. Our electrode table has the details.
  5. Choose a unit that matches that current and covers the voltage. If no single unit covers the circuit, split it into smaller circuits, each with its own suitably rated unit.

A worked example

A shop sign in 12mm blue tube, three sections, 4.3m of glass in total.

  • The neon calculator gives about 2,900V for a Hansen EVG indoors, about 3,290V outdoors, and about 4,000V for a SIET on blue.
  • 12mm tube runs on 50R (EL050) electrodes, 50mA maximum, so a 40mA unit sits comfortably inside that.
  • Indoors, choose a 40mA Hansen EVG whose voltage rating covers the estimated 2,900V, mounted close to the tubes on its supplied HT leads.
  • For the same sign outside, check the outdoor figure against the model, and remember the 5kV and 8kV Hansens aren't for outdoor use. The alternative is a SIET Metalbox with the right current rating and enough voltage for about 4,000V, mounted to SIET's instructions.

Every job is different, so check the model's datasheet and installation advice before you order. Our transformer sizing guide goes into more detail, and the dimmer and flasher picker checks your control gear. Or send us the tube diameters, gas, glass lengths and circuit layout and we'll recommend the unit: 01892 783 900.

Back to blog